The Advanced Photon Source
a U.S. Department of Energy Office of Science User Facility

Storage Ring Injection Magnets

Drawings

Tables

(31010502-700000) Operational Parameters *
Number 1
Minimum Septum Thickness 30 mm
Physical Length 1.79 m
Effective Length 1.75 m
Gap Height 30 mm
Gap Width 40 mm
Field at 7 GeV 1.08 T
Peak supply current 0.66 kA
Peak power 80 kW
Average power 0.797 kW

*data from H.B. 7/97

(31010501-800000) Operational Parameters *
Number 1
Minimum Septum Thickness 2 mm
Physical Length 1.06 m
Effective Length 1.05 m
Gap Height 20 mm
Gap Width 34 mm
Peak Field 0.73 T
Peak supply current 11.74 kA
Peak power 62 kW
Power 0.042 kW
Pulse width (1.5kHz half sine) 333 microsec

*data from H.B. 7/97