Cavity Component Temperature Diagnostics

  1. Cavity - Thermocouples (Chromel-Alumel)
        a. Upstream (US) Cavity Cover
        b. Downstream (DS) Cavity Cover
        c. Cavity Center
        d. 1.5-Inch US Water Manifold Supply and Return
        e. 1.5-Inch DS Water Manifold Supply and Return
        f. 0.75-Inch US Water Manifold Supply and Return
        g. 0.75-Inch DS Water Manifold Supply and Return
        h. Top Flange (Tuner Port)
        i. Side Flange (Coupler Port)
  2. Coupler - Infrared (Land Infrared)
        a. US Window Sensor
        b. DS Window Sensor
  3. Coupler - Thermocouples (Chromel-Alumel)
        a. Body Water Return
        b. Center Conductor Return
        c. Waveguide Air Supply and Return
  4. Tuner - Thermocouples (Chromel-Alumel)
        a. Mounting Flange - US, Aisle, DS, and Wall
        b. Tuner Piston - US, Aisle, DS and Wall
        c. Tuner Bellows
        d. Piston Water Return
        e. Housing Water Return
  5. Temperature Measurements
        a. Alarmed, (Not Interlocked), To Avoid Noise Trips
        b. Accessible Through EPICS
        c. Logged for Diagnostics and Preventive Maintenance