Cavity Component Temperature Diagnostics
- Cavity - Thermocouples (Chromel-Alumel)
a. Upstream (US) Cavity Cover
b. Downstream (DS) Cavity Cover
c. Cavity Center
d. 1.5-Inch US Water Manifold Supply and Return
e. 1.5-Inch DS Water Manifold Supply and Return
f. 0.75-Inch US Water Manifold Supply and Return
g. 0.75-Inch DS Water Manifold Supply and Return
h. Top Flange (Tuner Port)
i. Side Flange (Coupler Port) - Coupler - Infrared (Land Infrared)
a. US Window Sensor
b. DS Window Sensor - Coupler - Thermocouples (Chromel-Alumel)
a. Body Water Return
b. Center Conductor Return
c. Waveguide Air Supply and Return - Tuner - Thermocouples (Chromel-Alumel)
a. Mounting Flange - US, Aisle, DS, and Wall
b. Tuner Piston - US, Aisle, DS and Wall
c. Tuner Bellows
d. Piston Water Return
e. Housing Water Return - Temperature Measurements
a. Alarmed, (Not Interlocked), To Avoid Noise Trips
b. Accessible Through EPICS
c. Logged for Diagnostics and Preventive Maintenance